Terminology Mechanical

ME 102

Control contacts (optional)
a) Momentary contact dependent on speed when number 0000 has been reached (length of contact during one digit). Contact duration e.g. for 3000 digits / min = 15 ms. We recommend using the control contact as latched contact, as described under b), in case of speeds higher than 3000 digits/min
b) Latched contact when switching from 0000 to 9999, i.e. the preset value is to be reduced by one when selected. The contact remains latched until the counter is reset.

Leader contact (pre-contact)
Possible with additional unchanged pre-contact as momentary contact dependent on speed. The pre-contact can be set to any value you desire.
The main contact is then designed as latched contact.


ME 230

Unchangeable pre-contact

The counter may be equipped with an unchangeable pre-contact. Please note that the main contact can only be initiated when the counter switches from 00000 to 99999. The preset value will be reduced by one when selected. The pre-contact is designed as switching (latched) contact. The pre-contact can be set to any value you desire.


ME 280

Double presetting
Counters equipped with two presets allow the preselection of 2 different values.  They start adding at zero and activate a contact as soon as each of the preset values has been reached.
It is therefore possible to initiate two subsequent control sequences. To repeat the counting in the same sequence, you only need to push the reset lever once.

Preselection
Push the lateral lever, keep it in this position and then key in the value required in the sequence of your choice.
As soon as the preselection is completed, return the lateral lever to its initial position. This will lock the keys thus impairing any modification of the preset value should a key be inadvertently pushed.

Key reset
The reset button is locked on counters with key reset. It can only be operated by using the flat key supplied.

Reset to zero
The counter is set to the value 0000 by pushing the button and/or through an electric pulse.

Reset to initial value
The counter is set back to the preset value by pushing the button and/or through an electric pulse.

Pre contact
An unchangeable pre-contact (switching contact) that is activated prior to the main contact at an optional, fixed value.

   
  Back to IVO
   
  Related Mechanical Counters Products :
    Piece Counter Elec Impulse Counters  
    Stroke / Revol Counters Elec Presel Counters  
    Mech. Presel. Counters Accessories  
    Meter Counters Offer  
    Small Measurring Wheel Terminology  
    Big Measurring Wheel    
         
| News | P.T Oriental Abadi Indonesia
© 2003. PT. Oriental Abadi Indonesia.
All Rights Reserved.